Workstation cluster
(Haverkort, Hermanns & Katoen)
Contents
- Introduction
- Model Statistics
- Model Construction Times
- Steady State Probability Computation
- Model Checking
Introduction
This case study is based on a cluster of workstations, taken from [HHK00]. The system comprises two sub-clusters with N workstations in each, connected in a star topology. The switches connecting each sub-cluster are joined by a central backbone. All components can break down and there is a single repair unit to service all components.

We define two levels of Quality of Service (QoS):
- minimum QoS: at least 3N/4 workstations are operational and connected via switches and backbone;
- premium QoS: at least N workstations are operational and connected via switches and backbone.
The model is represented as a CTMC. The PRISM source code is given below.
// Workstation cluster [HHK00]
// dxp/gxn 11/01/00
ctmc
const int N; // Number of workstations in each cluster
const int left_mx = N; // Number of work stations in left cluster
const int right_mx = N; // Number of work stations in right cluster
// Minimum QoS requires 3/4 connected workstations operational
const int k = floor(0.75*N);
formula minimum = (left_n>=k & toleft_n) |
(right_n>=k & toright_n) |
((left_n+right_n)>=k & toleft_n & line_n & toright_n);
// Failure rates
const double ws_fail = 1/500; // Single workstation: average time to fail = 500 hrs
const double switch_fail = 1/4000; // Switch: average time to fail = 4000 hrs
const double line_fail = 1/5000; // Backbone: average time to fail = 5000 hrs
// Left cluster
module Left
left_n : [0..left_mx] init left_mx; // Number of workstations operational
left : bool; // Being repaired?
[startLeft] !left & (left_n<left_mx) -> 1 : (left'=true);
[repairLeft] left & (left_n<left_mx) -> 1 : (left'=false) & (left_n'=left_n+1);
[] (left_n>0) -> ws_fail*left_n : (left_n'=left_n-1);
endmodule
// Right cluster
module Right = Left[left_n=right_n,
left=right,
left_mx=right_mx,
startLeft=startRight,
repairLeft=repairRight ]
endmodule
// Repair unit
module Repairman
r : bool; // Repairing?
[startLeft] !r -> 10 : (r'=true); // Inspect Left
[startRight] !r -> 10 : (r'=true); // Inspect Right
[startToLeft] !r -> 10 : (r'=true); // Inspect ToLeft
[startToRight] !r -> 10 : (r'=true); // Inspect ToRight
[startLine] !r -> 10 : (r'=true); // Inspect Line
[repairLeft] r -> 2 : (r'=false); // Repair Left
[repairRight] r -> 2 : (r'=false); // Repair Right
[repairToLeft] r -> 0.25 : (r'=false); // Repair ToLeft
[repairToRight] r -> 0.25 : (r'=false); // Repair ToRight
[repairLine] r -> 0.125 : (r'=false); // Repair Line
endmodule
// Line/backbone
module Line
line : bool; // Being repaired?
line_n : bool init true; // Working?
[startLine] !line & !line_n -> 1 : (line'=true);
[repairLine] line & !line_n -> 1 : (line'=false) & (line_n'=true);
[] line_n -> line_fail : (line_n'=false);
endmodule
// Left switch
module ToLeft = Line[line=toleft,
line_n=toleft_n,
line_fail=switch_fail,
startLine=startToLeft,
repairLine=repairToLeft ]
endmodule
// Right switch
module ToRight = Line[line=toright,
line_n=toright_n,
line_fail=switch_fail,
startLine=startToRight,
repairLine=repairToRight ]
endmodule
// Reward structures
// Percentage of operational workstations stations
rewards "percent_op"
true : 100*(left_n+right_n)/(2*N);
endrewards
// Time that the system is not delivering at least minimum QoS
rewards "time_not_min"
!minimum : 1;
endrewards
// Number of repairs
rewards "num_repairs"
[repairLeft] true : 1;
[repairRight] true : 1;
[repairToLeft] true : 1;
[repairToRight] true : 1;
[repairLine] true : 1;
endrewardsModel Statistics
The table below shows statistics for each model we have built. The first section gives information about the CTMC representing the model: the number of states and the number of non zeros (transitions). The second part refers to the MTBDD which represents this CTMC: the total number of nodes, the number of leaves (terminal nodes), and the amount of memory needed to store it. The last column gives the amount of memory a sparse matrix would need to represent the same CTMC.
| N: | Model: | MTBDD: | Sparse: | |||
|---|---|---|---|---|---|---|
| States: | NNZ: | Nodes: | Leaves: | Kb: | Kb: | |
| 2 | 276 | 1,120 | 331 | 9 | 6.46 | 16.4 |
| 4 | 820 | 3,616 | 535 | 11 | 10.5 | 51.9 |
| 8 | 2,772 | 12,832 | 968 | 15 | 18.9 | 183 |
| 16 | 10,132 | 48,160 | 1,899 | 23 | 37.1 | 683 |
| 32 | 38,676 | 186,400 | 3,906 | 39 | 76.3 | 2,637 |
| 64 | 151,060 | 733,216 | 8,225 | 71 | 160 | 10,362 |
| 128 | 597,012 | 2,908,192 | 17,481 | 134 | 341 | 41,076 |
| 256 | 2,373,652 | 1.15e+7 | 37,272 | 262 | 728 | 162,581 |
| 512 | 9,465,876 | 4.6e+7 | 79,399 | 518 | 1,550 | 649,990 |
Model Construction Times
The table below gives the times taken to construct the models. This process involves first building a CTMC (represented as an MTBDD) from the system description (in our module based language), and then computing the reachable states using a BDD based fixpoint algorithm. The total time required and the number of fixpoint iterations are given below.
| N: | Construction: | |
|---|---|---|
| Time (s): | Iter.s: | |
| 2 | 0.14 | 9 |
| 4 | 0.15 | 13 |
| 8 | 0.20 | 21 |
| 16 | 0.05 | 37 |
| 32 | 0.12 | 69 |
| 64 | 1.65 | 133 |
| 128 | 6.20 | 261 |
| 256 | 23.43 | 517 |
| 512 | 100.96 | 1,029 |
Steady-State Probability Computation
The table below gives the times taken to compute the steady-state probabilities using the JOR method. The number of iterations required and the time taken using the MTBDD, sparse and hybrid engines is as follows.
| N: | Time per iteration: (s) | Iterations: | ||
|---|---|---|---|---|
| MTBDD | Sparse | Hybrid | ||
| 2 | 0.028 | 0.00026 | 0.00027 | 39 |
| 4 | 0.052 | 0.00031 | 0.00063 | 64 |
| 8 | 0.21 | 0.00085 | 0.0022 | 82 |
| 16 | 0.78 | 0.0035 | 0.0072 | 141 |
| 32 | 2.81 | 0.014 | 0.025 | 260 |
| 64 | 9.38 | 0.14 | 0.16 | 540 |
| 128 | 32.6 | 0.39 | 0.49 | 1,276 |
| 256 | - | - | 2.16 | 3,634 |
| 512 | - | - | 8.99 | 30,476 |
The steady-state probabilities allows use to compute properties such as:
S=? ["premium"]: the long-run probability that premium QoS will be delivered.S=? [ !"minimum"]: the long-run probability that QoS is below minimum.
Model Checking
We have model checked the following properties:
-
"The system will always be able to offer premium QoS at some point in the future." The corresponding CSL formula is given by:
P>=1 [ true U "premium" ]Model checking times:
N: Prob1 precomputation: Time (s): Iterations: 2 0.063 18 4 0.075 26 8 0.073 42 16 0.192 74 32 0.360 138 64 1.27 266 128 3.30 522 256 12.1 1034 512 44.3 2058 Conclusion: the property holds in all states
-
"The chance that the QoS drops below minimum quality within T time units." The corresponding CSL formula is given by
P=? [ true U<=T !"minimum" ]In the graph below we have plotted these probabilities from a range of values of
TandN.
-
"When facing insufficient QoS, the (maximum) probability of facing the same problem after T time units." The corresponding CSL formula is given by
P=? [ true U[T,T] !"minimum" {!"minimum"}{max} ]In the graph below we have plotted these probabilities from a range of values of
TandN.
-
"The probability of going from minimum QoS to premium QoS within T time units." The corresponding CSL formula is given by
P=? [ true U<=T "premium" {"minimum"}{min} ]In the graph below we have plotted these probabilities from a range of values of
TandN.
-
"The probability of going from minimum QoS to premium QoS within T time units without violating the minimum QoS constraint along the way." The corresponding CSL formula is given by
P=? [ "minimum" U<=T "premium" {"minimum"}{min}]In the graph below we have plotted these probabilities from a range of values of
TandN.
-
"The probability that it takes more than T time units to recover from insufficient QoS." The corresponding CSL formula is given by
P=? [ !"minimum" U>=T "minimum" {!"minimum"}{max} ]In the graph below we have plotted these probabilities from a range of values of
TandN.
-
"The minimum percentage of operational workstations at time T when starting from below minimum QoS." The corresponding CSL formula is given by
R{"percent_op"}=?[ I=T {!"minimum"}{min} ]In the graph below we have plotted these results from a range of values of
TandN.
-
"The expected time that the system is below minimum QoS until time T." The corresponding CSL formula is given by
R{"time_not_min"}=?[ C<=T ]In the graph below we have plotted these results from a range of values of
TandN.

-
"The expected number of repairs by time T." The corresponding CSL formula is given by
R{"num_repairs"}=?[ C<=T ]In the graph below we have plotted these results from a range of values of
TandN.